вторник, 10 ноября 2009 г.

выпрямитель на диодных модулях SKKD100/12 и чоппером на SEMIX352GB128D -тепловой расчет

Project:KRIPTO iK
TopologyAC/DC
CircuitB2U
Circuit:
Vin18 V
Iout120 A
Iout rms120 A
fin50 Hz
Form Factor1.4142
Overload Factor1
Overload Duration 10 sec
Device:
Product LineSemiPack
Device SKKD100*
Recommended Voltage200 V
Maximum Junction Temperature 125 °C
Use Maximum ValuesYes
VT0.25 =1.06 VVT0.125 =0.86 V
rT.25 =1.03 mOhmrT.125 =1.37 mOhm
Rth(j-s) =0.55 K/W
Data set from Not set
No Comment
Cooling:
Ambient temperature35 °C
Number of switches per heat sink4
Number of parallel devices on the same heat sink 1
Additional power source at this heat sink190 W -доп.потери от SEMIX352GB128
Predefined SK-Heat SinkP3_180 -используем аналог охладитель RE180
Correction Factor1
Forced Air Cooling, Flow Rate:150 m3/h
Rth(s-a)0.117 K/W
Losses And Temperatures:
Steady StateOverload
Lossesdevice62 W62 W
Lossestot248 W248 W
Heat Sink Temperature86 °C86 °C
Junction Temperature120 °C120 °C
Evaluation:
Recommendation by SEMIKRON: Do not use semiconductor in the range of Tj(max) = 125 °C
Note
1) A: 15V - Vin; B: 5V - Vin

Комментариев нет:

 

Форум инженеров по автоматизации, электроников и приводистов